1. The rotor of the centrifugal pump is unbalanced and misaligned. This problem accounts for a large proportion of the vibration problems of centrifugal pumps, about 80%. Factors causing the imbalance of the rotor of the centrifugal pump: uneven material resistance, unqualified parts structure, resulting in the imbalance between the center line of the rotor mass and the center line of the rotating shaft, resulting in eccentricity. Correction of rotor imbalance of centrifugal pump can be divided into two categories. Static balance and dynamic balance: also known as single-sided balance and double-sided balance. The difference is: single-sided balancing is performed on one correction plane, while double-sided balancing is performed on two correction planes.
2. Installation reasons: the foundation bolts are loose, and the level of the adjustment is not adjusted properly. Before the centrifugal pump works, it is necessary to check whether the foundation bolts are loose and whether the installation of the centrifugal pump is level. These will also cause the centrifugal pump to vibrate during operation.
3. There is a foreign body in the centrifugal pump. Before the centrifugal pump works, check the inside of the lower pump. Due to long-term use, there may be some foreign objects such as weeds in the water.
4. Cavitation perforation inside the centrifugal pump due to long-term use.