Aug 15, 2022

1. Roots vacuum pump suction is too high

Check the existing net head, it may be that the inlet pipe is too small and the inlet pipe is too long due to friction.

2. Impeller or pipe blockage

Check for blockages.

3. There is a leak in the air or inlet pipe

Check the inlet piping for cavities or leaks.

4. The packing is in the stuffing box or the seal is worn, so that the air leaks into the pump

Check packing or seals and replace as needed, check for proper lubrication.

5. When the roots vacuum pump out hot volatile liquid, the water head is insufficient

The water head should increase, ask the manufacturer.

6. The immersion depth of the bottom valve or inlet pipe is not enough

Ask about the correct immersion depth and use baffles to resolve eddies.

7. The sealing gasket of the Roots vacuum pump casing is damaged

Carry out maintenance inspections.