Call Us: +8613573317266Email: 947633108@qq.com
enLanguage
Vertical Desander Pump

Vertical Desander Pump

YZ type vertical submerged desander pump is a vertical single-stage single-suction cantilever centrifugal pump structure. The impeller is a semi-open impeller, and a stirring blade is provided at the extension of the suction side of the impeller.

YZ type vertical submerged desander pump is a vertical single-stage single-suction cantilever centrifugal pump structure. The impeller is a semi-open impeller, and a stirring blade is provided at the extension of the suction side of the impeller.The two series pumps are mainly used for environmental protection, municipal engineering, thermal power plants, gas coking plants, oil refineries, mining, papermaking, cement plants, food plants, printing and dyeing industries to pump concentrated liquid, heavy oil, oil residue, dirty liquid, mud, mortar, flowing sand and flowing sludge from urban sewage channels, as well as liquids containing coal blocks and ash. It can also be used to pump fluids and corrosive liquids containing sludge and slag in chemical, pharmaceutical and other industries. YW type can also pump all kinds of human and livestock manure sewage and large and medium-sized biogas digesters, which are used for discharge in biogas engineering.


80YZ80-20A

YZ-submerged slurry pump

80-Outlet diameter of the pump (mm)

80-Design point flow rate of the pump (m3/h)

20-Design point head of the pump (m)

A-impeller is cut for the first time


YZ type vertical submerged desander pump is a single-stage, single-suction cantilever structure, The hydraulic components of the pump are connected with a bearing seat, a support seat, and a connecting pipe. The liquid is discharged from the liquid outlet pipe component, the impeller of the pump is a semi-open impeller, and there is no stirring blade at the extension of the suction edge of the impeller. The main characteristics of the pump are that the pump shaft under the liquid has sufficient rigidity, there is no bearing between the impeller and the pump shell, and the medium containing large concentration of solid particles can be transported without shaft seal. The length of the pump into the liquid is between 800 and 1800, and it can be equipped with a suction pipe if necessary. The shaft seal is run by a submerged pump inserted into the liquid, without a shaft seal. The transmission is installed on the motor support and the support seat by a vertical motor, and is connected with the pump by a coupling.


Assembly sequence of YZ type submerged pump:

(1) Install the bearings on the bearing box and the bearing seat respectively.

(2) Install the oil seal felt ring on the bearing end cover A, C and bearing box respectively.

(3) Install the bearing end covers B and C on the bearing seat and fasten them with bolts.

(4) Put the installed bearing box on the shaft, screw on the round nut, and fasten the bearing end cover on the bearing box.

(5) Install the shaft into the bearing seat, fix it with bolts, screw on the adjusting screws, install the bearing seat on the supporting seat, and put the water retaining ring in the proper position of the lower bearing.

(6) Fix the connecting pipe on the bearing seat, and install the pump cover at the lower part of the connecting pipe, install the impeller at the lower part of the shaft and tighten it, install the front cover of the pump body in turn, and fix it with bolts, adjust the gap between the impeller and the front cover with the adjusting screws at the bearing box (controlled within 1-1.5 mm), and fasten it with nuts and bolts after adjustment.

(7) The motor support is installed on the bearing seat and fastened with bolts, and the coupling parts are installed on the upper end of the shaft, and the motor coupling is fastened on the motor shaft head with fastening screws, and the motor is installed on the motor support and fastened with bolts and nuts.

(8) Install the asbestos pad, the liquid outlet elbow and the liquid outlet pipe components in sequence from the outlet of the pump and fix them on the supporting seat. Disassembly of the pump shall be carried out according to the above steps in reverse.


Operation

1. Pay attention to the temperature of the pump shaft, which should not exceed the external temperature by 35 ℃, but should not exceed 75°C at the highest.

2. The oil cup should be filled with calcium-based butter to ensure that the bearing can be lubricated normally.

3. In the first month of operation, or after 100 hours of operation, the butter in the motor supporting oil cup should be replaced. In the future, it will be replaced after every 2000 hours of work.

4. Regularly check the elastic coupling regularly and pay attention to the temperature rise of the motor bearings.

5. In the process of operation, if any noise or unusual sound is found, stop immediately for inspection.

6. The pump should be checked periodically every 2000 hours of operation. The wear of the gap between the impeller pump body (or pump cover) should not be too large, and the maximum value of the gap should not exceed 1.5 meters. If it exceeds, the impeller or front cover can be replaced.


Possible faults and their solutions

Faults

Reason

Solution

The pump does not produce water

Pressure gauge pointer jumps violently

The water inlet is silted up

Air leakage from pipes and instruments

Discharge silt

Tighten or block the deep air

The pump does not produce water

Rotate in the wrong direction

The pump inlet is higher than the liquid level

Check motor steering

Raise the liquid level or lower the installation height of the pump

The pressure gauge indicates that there is pressure at the outlet of the pump

The pump still doesn't produce water

The outlet pipe is too blocked

Impeller fouling, insufficient revolutions

Increase the speed of the pump

Check the pipeline and clean the impeller

Low flow rate

Water pump blockage

Insufficient revolution impeller wear is too large

Cleaning the pump and the pipeline

Add crucible revolution and replace the impeller

Excessive power consumption of pump

Impeller wear

The pump water supply is too small (or completely closed)

Replace the impeller

The outlet pipe opens the gate valve

Bearing overheating

Bearing oil shortage

Dirt or damage inside the suction bearing

Add grease

Clean or replace the bearings


image003

image007

image011


Send Inquiry

(0/10)

clearall